CLEARjet GmbH CX-one
Save parameter <ESC>Ms
Description
Save all parameters to EEPROM
Note: Power down or a printer reset within 5 sec. after
using this command may cause unpredictable results.
ASCII – Code
<ESC>Ms
HEX – Code
1B 4D 73
Restore parameter <ESC>Mr
Description
Restore all parameters from EEPROM
ASCII – Code
<ESC>Mr
HEX – Code
1B 4D 72
Read parameter from EEPROM <ESC>Ml [nn]
Description
Read a specified parameter from EEPROM
[nn] parameter-code (See table on next page).
ASCII – Code
<ESC>Ml [nn]
HEX – Code
1B 4D 6C [nn]
Example
<ESC>Ml00
Read printenergy value from EEPROM
Response : +00150
Return-Parameter
from printer
1 char. sign
5 numerical characters